HAWC2 IEC 61400-1 NREL 5MW
This file contains an excel sheet for generating input files for the IEC 61400-1 load cases. The master file is based on the NREL 5MW reference turbine. The excel sheet can be used in general to generate new input files based on a master file by adding or reducing variable parameters in the top of the excel sheet3.
Version 4:
-Corrected wrong names
-EOG changed to NTM in DLC 5.1
Version 3:
-Updated design for a better overview
-Auto specification of hawc2 folder
-Reorganization of files for a better overview
Version 2:
-Corrected a bug in calculation of the A-parameter in the EWS model
Quick guide
1. Sheet: Main
Enable macros.
2. Sheet: input
If covering the IEC61400-1 Load basis insert all values in the green cells from the standard.
3. Sheet: Loadcases
Check all inputs and if you wish to remove any load cases clear the cells in row “Sim. to run”. Click

to generate all HTC-input files and the batch file. Mark “run local” and click “ok”. (jobs after an empty field in the “Job id.” Will not be run)
remember to set decimal symbol to . in Windows (Control Panel\Clock,Language, and Region\Change the date, time, or number format\Format\additional settings)